Senior HV Cable Tester | Underground Diagnostics New

Hudson · East Melbourne VIC 3002 · Full time
Posted 3d ago

Senior HV Cable Tester | Underground Diagnostics New

Hudson
~$130k - $170k(Estimated)
Hudson Logo
KEY POINTS WE FOUND
  • Lead a two-person crew as Tester in Charge, carrying out high-voltage underground cable testing and diagnostics on utility and major energy network assets.
  • Perform Tier 1 and Tier 2 tests, including partial discharge, Tan Delta, TDR, sheath testing and cable fault location; maintain test equipment and validate reports.
  • Bring substantial HV cable testing and TIC experience, relevant electrical qualifications and authorities, and flexibility for night shifts and statewide travel.

Sole pioneers of breakthrough cable remediation technology Fast-growing company with cutting-edge technology Utility & major energy network assets


About the Opportunity

Our client is a leading infrastructure solutions specialist expanding its advanced high voltage underground diagnostics division across Victoria. As a pioneer in next-generation cable remediation, the company is introducing a first-of-its-kind technology that sets a new industry standard. The company is transforming how infrastructure is maintained across the country. Holding  exclusive ownership of the tech in Australia it offers the opportunity for a solution that literally doesn't exist anywhere else in the country saving clients significant time and capital compared to traditional methods.

We are seeking an experienced Senior HV Cable Tester to take technical ownership in the field, acting as Tester in Charge (TIC) on utility and major energy network assets. In this hands-on leadership role, you will lead a dedicated two-person testing crew delivering cutting-edge underground cable diagnostic services including resonant test sets, advanced Tan Delta, and world-class 50Hz Partial Discharge (PD) assessments.

This position offers long-term career stability, exposure to tier-one utility networks, and the opportunity to pioneer specialized testing methodologies.

Key Responsibilities

  • Lead a two-person crew, taking full accountability as Tester in Charge (TIC) under a Sanction for Test (SFT) in accordance with Victorian network operator standards and safety regulations.
  • Confirm isolation points, operational and work-party earths, manage complementary SFTs, and oversee remote-end safety protocols.
  • Advanced Diagnostics (Tier 1 & Tier 2):
    • Conduct 50Hz Partial Discharge (PD) assessments and circuit sensitivity verifications on new and in-service underground cable networks.
    • Deliver Tier 1 testing: continuity, phasing, sheath insulation/DC withstand, sheath fault location, and HV withstand testing.
    • Execute Tier 2 testing: Time Domain Reflectometry (TDR), Tan Delta, and complex cable fault location using resonant/VLF test systems.
  • Maintain advanced mobile test vehicles, resonant sets, and PD diagnostic gear; verify calibration records, upload testing data, and validate analytical reports.
  • Interface directly with network operators and asset owners to communicate condition reports and remedial strategies; mentor and coach junior test technicians.

What You Bring

Qualifications & Licences:

  • One of the following technical pathways:
  • Advanced Diploma of ESI – Power Systems (UET60222 or equivalent), OR
  • Certificate III in ESI – Distribution Underground (UET30821) with Conduct HV Testing of Underground Power Cable Systems (UETDRDU001), OR
  • Certificate III in Electrotechnology Electrician (UEE30820) with HV cable testing competencies.
  • Current Australian Driver Licence (Heavy Rigid / HR preferred).
  • Authority to Receive Electrical Access Permits (UETDRMP001).
  • AusNet Tier 2 HV Cable Tester Authority and SFTUG-TIC Authority (or the clear ability to obtain within 3 months).
  • Victorian A-Grade Electrical Licence and High Risk EWP (WP) are highly regarded.

Experience & Attributes:

  • 5+ years of experience conducting HV cable testing across utility, renewable, or heavy industrial infrastructure.
  • 2+ years acting as Tester in Charge (TIC) under SFT frameworks.
  • Solid working knowledge of the Victorian Blue Book (ESV), Green Book (VESI), and network access regimes.
  • Proven track record operating resonant, VLF, or DAC test sets, alongside cable fault location instrumentation.
  • Flexibility to accommodate planned night shifts, outage windows, and statewide travel as required.

Enquiries to Pat Hart on 0439074391

Diversity, Equity & Inclusion at Hudson
Hudson is committed to helping you find a workplace where you feel respected, supported, and free to thrive. We welcome applications from all backgrounds, identities, and lived experiences—because when different voices come together, amazing things happen.

Consultant

Pat.Hart@hudson.com

Reference number: 250788
Profession:EngineeringElectrical/Electronic Engineering

Company: Hudson
Date posted: 12th Nov, 2026

Stay Safe While Job Hunting

We vet all employer accounts and do our best to keep job ads safe, but scams can still occur. Be cautious when sharing personal information — never provide financial details or make payments during the application process. For extra security, use the Apply button on our site when proceeding.

Skills

0 of 29 matched
Australian driver licenceCable fault locationCalibration records managementCircuit sensitivity verificationContinuity testingCrew leadershipDac testingElectrical access and isolation safetyFlexibilityHeavy vehicle drivingHv cable testingHv withstand testingMentoringPartial discharge testingPhasingResonant test systemsSafety leadershipSanction for test proceduresSheath insulation testingStakeholder communicationTan delta testingTechnical report validationTest equipment maintenanceTesting data analysisTime domain reflectometryUnderground cable diagnosticsVesi green bookVictorian blue bookVlf testing

Licenses & certifications

0 of 11 matched
Advanced diploma of esi - power systems (uet60222 or equivalent)Ausnet tier 2 hv cable tester authorityAustralian driver licenceAuthority to receive electrical access permits (uetdrmp001)Certificate iii in electrotechnology electrician (uee30820) with hv cable testing competenciesCertificate iii in esi - distribution underground (uet30821)Conduct hv testing of underground power cable systems (uetdrdu001)Heavy rigid (hr) driver licenceHigh risk work licence - wp (ewp)Sftug-tic authorityVictorian a-grade electrical licence

Perks & benefits

0 of 3 matched
Exposure to tier-one utility networksLong-term career stabilityOpportunity to pioneer specialised testing methodologies